Category
PLC 1000L/H RO Water Treatment System SUS Industrial Drinking Water Filter Machine Reverse Osmosis Purification Purifier Plant
Overview PLC 1000L/H RO Water Treatment System SUS Industrial Drinking Water Filter Machine Reverse Osmosis Purification
Overview
Detailed PhotosWater Pumps---Raw Water Pumps, CIP washing pumps and High Pressure Pumps: 1.Brand: We can offer standard CNP brand2.Material: Can be SUS-304 for fresh water purification, or SUS-316 for salty/brackish water desalination.3.Name and Function:Raw water pump to provide pressure for pre-treatment part.High pressure pump to provide pressure for Ro membranes.CIP Washing pump for membranes maintenance.
PLC Touch Screen Control System1--Company name and logo design: customize as your requirements.2--Language:English, Spanish, French and so on.3--Conductivity meter: display the conductivity of output water.4--PH meter: display the PH of output water5--Thermometer: display the temperature of output water
Basic Info.
Model NO. | KYRO-1000L/H |
Trademark | KAIYUAN |
Origin | China |
HS Code | 842121 |
Production Capacity | 200 Sets/Month |
Product Description
PLC 1000L/H RO Water Treatment System SUS Industrial Drinking Water Filter Machine Reverse Osmosis Purification Purifier Plant
Product DescriptionReverse Osmosis System is an equipment to purify the saltine water with the action of pressure difference of semi permeable membrane. RO is also effective with asbestos, many taste, color and odor producing chemicals, particulates, total dissolved solids, turbidity and radium.Reverse Osmosis System can remove large particle, colloid, organic impurity, heavy metal ion, bacteria from water, and it can also remove more than 97% dissolved salt and solid.1.Electricity supply:110v-480v, 50hz or 60hz,3 phases |
2.Capacity:500L/H or customized from 500L/H to 100Ton/H |
3.Membranes Brands:DOW(Dupont) or Toray or Vontron |
4.Pumps: a) raw/feed water pump of CNP Brand; b) CIP Washing pump of CNP Brand; c) high pressure pump of CNP Brand; d) SEKO Brand anti-scale dosing pumps. UV sterilizer/Ozone generator, CIP washing system, anti-scale dosing system is for optional |
Specified configurationRO system(Each part is optional, for reference) | |||
Item | Material/Model | Brand | Function |
Raw water pump | SS304/SS316 | Lingxiao/CNP | Provide pressure for raw water |
Quartz sand filter | FRP/SUS304 /SS316 | kaiyuan, China | Get rid of turbidity, suspended matter, colloid, etc. |
Activated carbon filter | FRP/SUS304 /SS316 | kaiyuan, China | Remove the color, free chloride, organic matter, absorb odor, smell, etc... to make clear water |
Anti-scale chemical dosing system /water softener(optional) | FRP/SUS304 /SS316 | kaiyuan, China | Remove Calcium ion(Ca2+) and magnesium ion(Mg2+), removing hardness from water. |
Security filter | PVC or SUS304 1mircon/5mircon | kaiyuan, China | Block impurities greater than 5micron(1micron) |
High pressure pump | SS304/SS316 | Lingxiao/CNP | Provide pressure for water into RO membrane |
UV Sterilzier(Optional) | 0.5T/H | China | Kill 99% bacterial (For drinking directly) |
Ozone generator (Optional) | OZ-3G | China | Kill 99%bacterial and keep 2hours.(For making bottled water) |
CIP Washing system (optional) | including washing tank and pump | China | Membranes' washing and maintenance |
Solenoid valves, gauges,switch.. | Cooper/SUS-304 /SUS-316 | China | To protect the machine under operation |
Electronic control system | PLC Program control system or PC Program control system | kaiyuan, China | including Water conductivity monitor, AC contactor, Air switch, indicator light, knob switch, electrical miscellaneous... PH meter and thermometer is optional. |
Detailed PhotosWater Pumps---Raw Water Pumps, CIP washing pumps and High Pressure Pumps: 1.Brand: We can offer standard CNP brand2.Material: Can be SUS-304 for fresh water purification, or SUS-316 for salty/brackish water desalination.3.Name and Function:Raw water pump to provide pressure for pre-treatment part.High pressure pump to provide pressure for Ro membranes.CIP Washing pump for membranes maintenance.
Pre-treatment filters:1--The quartz sand filter: to remove the suspend solid and reduce the turbidity of outlet water .2--The activated carbon filter: to remove color, odor, residual chlorine from the raw water.3--Water Softener (optional): to remove Calcium ion (Ca2+) and magnesium ion(Mg2+) to remove hardness.Automatic control valve:It can automatically complete the fast rinsing and backwashing of filter materials, and then automatically turn to filter (normal operation) by setting the time on the program |
6--PLC(Programmable Logic Controller): Design the progaram as requirements you need.
7--PLC extension module, analog output module.8--Air switch:protect the electric system.
9--AC contactor, thermal relay
10--Indicator light, knob switch
11-- Intermediate relay, Fuse box
12-- Terminals, miscellaneous pieces of electrical appliances
13--When the raw water pump or high pressure pump overheat, relay will stop. So it can protect water pumps from damage.
RO membraneModel: LCLE-4040 Quantity:4 pcsBrand: Dupont, USA (Top in the world,with high quality and good reputation)Model: ULP31-4040 Quantity:4pcsBrand:VONTRON, made in ChinaThe service life is about 2 years. It can remove particle, colloid, organic impurity, heavy metal ion, bacteria and virus from water,and it can also remove more than 97% dissolved salt.Optional membrane brand : Toray & HYDECANME & Vontron ...Packaging & ShippingCompany ProfileCertificationsInstallation Instructions